TY - JOUR
T1 - Accuracy of stress myocardial perfusion imaging to diagnose coronary artery disease in end stage liver disease patients
AU - Bhutani, Suchit
AU - Tobis, Jonathan
AU - Gevorgyan, Rubine
AU - Sinha, Arjun
AU - Suh, William
AU - Honda, Henry M.
AU - Vorobiof, Gabriel
AU - Packard, René R.S.
AU - Steadman, Randolph
AU - Wray, Christopher
AU - Busuttil, Ronald
AU - Tseng, Chi Hong
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013/4/1
Y1 - 2013/4/1
N2 - Patients with end-stage liver disease (ESLD) who also have underlying coronary artery disease (CAD) may be at increased risk for undergoing hemodynamically challenging orthotopic liver transplantation. Noninvasive single-photon emission computed tomographic (SPECT) imaging is often used to determine whether a patient with ESLD has unsuspected CAD. The objective of this study was to determine the accuracy of SPECT imaging for detection of CAD in patients with ESLD. Patients with ESLD who underwent coronary angiography and SPECT imaging before orthotopic liver transplantation were analyzed retrospectively. The predictive accuracy of clinical risk factors was calculated and compared to the results of SPECT imaging. There were 473 SPECT imaging studies. Adenosine SPECT imaging had a sensitivity of 62%, specificity of 82%, positive predictive value of 30%, and negative predictive value of 95% for diagnosing severe CAD. Regadenoson SPECT imaging had a sensitivity of 35%, specificity of 88%, positive predictive value of 23%, and negative predictive value of 93% for diagnosing severe CAD. The accuracy of a standard risk factor analysis showed no statistical difference in predicting CAD compared with adenosine (sensitivity McNemar's p = 0.48, specificity McNemar's p = 1.00) or regadenoson (sensitivity McNemar's p = 0.77, specificity McNemar's p = 1.00) SPECT studies. In conclusion, the 2 pharmaceutical agents had low sensitivity but high specificity for diagnosing CAD. However, because the sensitivity of the test is low, the chances of missing patients with ESLD with CAD is high, making SPECT imaging an inaccurate screening test. A standard risk factor analysis as a predictor for CAD in patients with ESLD is less expensive, has no radiation exposure, and is as accurate as SPECT imaging.
AB - Patients with end-stage liver disease (ESLD) who also have underlying coronary artery disease (CAD) may be at increased risk for undergoing hemodynamically challenging orthotopic liver transplantation. Noninvasive single-photon emission computed tomographic (SPECT) imaging is often used to determine whether a patient with ESLD has unsuspected CAD. The objective of this study was to determine the accuracy of SPECT imaging for detection of CAD in patients with ESLD. Patients with ESLD who underwent coronary angiography and SPECT imaging before orthotopic liver transplantation were analyzed retrospectively. The predictive accuracy of clinical risk factors was calculated and compared to the results of SPECT imaging. There were 473 SPECT imaging studies. Adenosine SPECT imaging had a sensitivity of 62%, specificity of 82%, positive predictive value of 30%, and negative predictive value of 95% for diagnosing severe CAD. Regadenoson SPECT imaging had a sensitivity of 35%, specificity of 88%, positive predictive value of 23%, and negative predictive value of 93% for diagnosing severe CAD. The accuracy of a standard risk factor analysis showed no statistical difference in predicting CAD compared with adenosine (sensitivity McNemar's p = 0.48, specificity McNemar's p = 1.00) or regadenoson (sensitivity McNemar's p = 0.77, specificity McNemar's p = 1.00) SPECT studies. In conclusion, the 2 pharmaceutical agents had low sensitivity but high specificity for diagnosing CAD. However, because the sensitivity of the test is low, the chances of missing patients with ESLD with CAD is high, making SPECT imaging an inaccurate screening test. A standard risk factor analysis as a predictor for CAD in patients with ESLD is less expensive, has no radiation exposure, and is as accurate as SPECT imaging.
UR - http://www.scopus.com/inward/record.url?scp=84875226965&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875226965&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2012.12.023
DO - 10.1016/j.amjcard.2012.12.023
M3 - Article
C2 - 23337839
AN - SCOPUS:84875226965
SN - 0002-9149
VL - 111
SP - 1057
EP - 1061
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 7
ER -