TY - JOUR
T1 - Use of Advanced CT Technology to Evaluate Left Atrial Indices in Patients with a High Heart Rate or with Heart Rate Variability
T2 - The Converge Registry
AU - Cherukuri, Lavanya
AU - Birudaraju, Divya
AU - Kinninger, April
AU - Chaganti, Bhanu T.
AU - Pidikiti, Sivakrishna
AU - Pozon, Ryan G.
AU - Pozon, Anne Concepcion G.
AU - Lakshmanan, Suvasini
AU - Dahal, Suraj
AU - Hamal, Sajad
AU - Flores, Ferdinand
AU - Christopher, Dialing
AU - Andreini, Daniele
AU - Pontone, Gianluca
AU - Conte, Edoardo
AU - Nakanishi, Rine
AU - O'Rourke, Rachael
AU - Hamilton-Craig, Christian
AU - Nasir, Khurram
AU - Roy, Sion K.
AU - Mao, Song Shou
AU - Budoff, Matthew J.
N1 - Publisher Copyright:
COPYRIGHT © 2021 by the Society of Nuclear Medicine and Molecular Imaging
PY - 2021/3/1
Y1 - 2021/3/1
N2 - We intended to assess the ability of current-generation 256-slice coronary CT angiography (CCTA) to measure left atrial volume (LAV), comparing patients with a high heart rate (HiHR) of at least 70 bpm and patients with heart rate variability such as atrial fibrillation (AFib). Methods: Using the prospective Converge Registry of patients undergoing 256-detector CCTA on a Revolution scanner, we enrolled 121 HiHR patients (74 men; mean age, 62.7 ± 12.5 y) and 102 AFib patients (72 men; mean age, 60.5 ± 11.0 y) after obtaining informed consent. Quantitative data analysis of LAV was performed using automated methods, and end-systolic phases were chosen for measurements from CCTA. A Student t test, Wilcoxon rank-sum test, or χ2 test assessed baseline parameters. Univariate and multivariate linear regression analysis was used to assess LAV and LAV index (LAVI) while adjusting potentially confounding variables. Results: Mean LAV was significantly higher in AFib subjects (148.6 ± 57.2 mL) than in HiHR subjects (102.1 ± 36.5 mL) (P, 0.0001). Similarly, mean LAVI was significantly higher in AFib subjects (72.4 ± 28.1 mL/m2) than in HiHR subjects (51.5 ± 19.0 mL/m2) (P, 0.0001). After adjusting for age, body mass index, sex, diabetes, hypertension, hyperlipidemia, and smoking, subjects with AFib had, on average, LAV measures higher by 41.2 ± 6.7 mL and LAVI values higher by 23.1 ± 3.4 mL/m2 (P, 0.0001). Conclusion: Misalignment and motion artifacts in CCTA images affect diagnostic CT performance, especially in patients with elevated heart rates or profound arrhythmia. However, the new-generation Revolution CCTA provides detailed information on left-atrium-complex morphology and function, in addition to coronary anatomy, in HiHR and AFib patients without additional radiation, scanning, or contrast requirements.
AB - We intended to assess the ability of current-generation 256-slice coronary CT angiography (CCTA) to measure left atrial volume (LAV), comparing patients with a high heart rate (HiHR) of at least 70 bpm and patients with heart rate variability such as atrial fibrillation (AFib). Methods: Using the prospective Converge Registry of patients undergoing 256-detector CCTA on a Revolution scanner, we enrolled 121 HiHR patients (74 men; mean age, 62.7 ± 12.5 y) and 102 AFib patients (72 men; mean age, 60.5 ± 11.0 y) after obtaining informed consent. Quantitative data analysis of LAV was performed using automated methods, and end-systolic phases were chosen for measurements from CCTA. A Student t test, Wilcoxon rank-sum test, or χ2 test assessed baseline parameters. Univariate and multivariate linear regression analysis was used to assess LAV and LAV index (LAVI) while adjusting potentially confounding variables. Results: Mean LAV was significantly higher in AFib subjects (148.6 ± 57.2 mL) than in HiHR subjects (102.1 ± 36.5 mL) (P, 0.0001). Similarly, mean LAVI was significantly higher in AFib subjects (72.4 ± 28.1 mL/m2) than in HiHR subjects (51.5 ± 19.0 mL/m2) (P, 0.0001). After adjusting for age, body mass index, sex, diabetes, hypertension, hyperlipidemia, and smoking, subjects with AFib had, on average, LAV measures higher by 41.2 ± 6.7 mL and LAVI values higher by 23.1 ± 3.4 mL/m2 (P, 0.0001). Conclusion: Misalignment and motion artifacts in CCTA images affect diagnostic CT performance, especially in patients with elevated heart rates or profound arrhythmia. However, the new-generation Revolution CCTA provides detailed information on left-atrium-complex morphology and function, in addition to coronary anatomy, in HiHR and AFib patients without additional radiation, scanning, or contrast requirements.
KW - arrhythmia
KW - heart rate variability
KW - high heart rate
KW - left atrial volume
KW - motion artifacts
UR - http://www.scopus.com/inward/record.url?scp=85102602590&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85102602590&partnerID=8YFLogxK
U2 - 10.2967/jnmt.120.253781
DO - 10.2967/jnmt.120.253781
M3 - Article
C2 - 33219160
AN - SCOPUS:85102602590
SN - 0091-4916
VL - 49
SP - 65
EP - 69
JO - Journal of Nuclear Medicine Technology
JF - Journal of Nuclear Medicine Technology
IS - 1
ER -