Whole-body biodistribution and radiation dosimetry in monkeys and humans of the phosphodiesterase 4 radioligand [11C](R)-rolipram: comparison of two-dimensional planar, bisected and quadrisected image analyses

David R. Sprague, Masahiro Fujita, Yong Hoon Ryu, Jeih San Liow, Victor W. Pike, Robert B. Innis

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Introduction: [11C](R)-Rolipram is a selective radioligand for positron emission tomography (PET) imaging of phosphodiesterase 4, an enzyme that metabolizes 3′,5′-cyclic adenosine monophosphate. The aim of this study was to estimate the human radiation absorbed dose of the radioligand based on its biodistribution in both monkeys and humans. Methods: Whole-body PET images were acquired for 2 h after injecting [11C](R)-rolipram in eight healthy humans and three monkeys. The simple method of using a single two-dimensional (2D) planar image was compared to more time-consuming methods that used two (bisected) or four (quadrisected) tomographic images in the anteroposterior direction. Results: Effective dose was 4.8 μGy/MBq based on 2D planar images. The effective dose was only slightly lower by 1% and 5% using the bisected and quadrisected images, respectively. Nevertheless, the two tomographic methods may have more accurately estimated the exposure of some organs (e.g., kidneys) that are asymmetrically located in the body or have radioactivity that appears to overlap on 2D planar images. Monkeys had a different biodistribution pattern compared to humans (e.g., greater urinary excretion) such that their data overestimated the effective dose in humans by 40%. Conclusions: The effective dose of [11C](R)-rolipram was modest and comparable to that of other 11C-labeled radioligands. The simple and far less time-consuming 2D planar method provided accurate and somewhat more conservative estimates of effective dose than the two tomographic methods. Although monkeys are commonly used to estimate human radiation exposures, their data gave a considerable overestimation for this radioligand.

Original languageEnglish (US)
Pages (from-to)493-500
Number of pages8
JournalNuclear Medicine and Biology
Volume35
Issue number4
DOIs
StatePublished - May 2008

Keywords

  • Biodistribution
  • Dosimetry
  • Positron emission tomography
  • [C](R)-Rolipram

ASJC Scopus subject areas

  • Molecular Medicine
  • Radiology Nuclear Medicine and imaging
  • Cancer Research

Fingerprint

Dive into the research topics of 'Whole-body biodistribution and radiation dosimetry in monkeys and humans of the phosphodiesterase 4 radioligand [11C](R)-rolipram: comparison of two-dimensional planar, bisected and quadrisected image analyses'. Together they form a unique fingerprint.

Cite this