TY - JOUR
T1 - Zero filled partial Fourier phase contrast MR imaging
T2 - In vitro and in vivo assessment
AU - Szarf, Gilberto
AU - Dori, Yoav
AU - Rettmann, Dan
AU - Tekes, Aylin
AU - Nasir, Khurram
AU - Amado, Luciano
AU - Foo, Thomas K.F.
AU - Bluemke, David A.
PY - 2006/1
Y1 - 2006/1
N2 - Purpose: To validate partial Fourier phase contrast magnetic resonance (PC MR) with full number of excitation (NEX) PC MR measurements in vitro and in vivo. Materials and Methods: MR flow measurements were performed using a partial Fourier and a full NEX PC MR sequence in a flow phantom and in 10 popliteal and renal arteries of 10 different healthy volunteers. Average velocity, peak velocity, and flow results were calculated and compared with regression analysis. Results: Excellent correlations in average velocities (r = 0.99, P < 0.001), peak velocities (r = 0.99, P < 0.001), and flow rates (r = 0.98, P < 0.001) were demonstrated in vitro between the two different acquisitions. For the popliteal arteries there was excellent correlation between peak velocities for both acquisitions (r = 0.98, P < 0.0001); the correlation of average velocity measurements when using all data points in the cardiac cycle for all volunteers was 0.96 (P < 0.001). For the renal arteries the same comparison resulted in a good correlation for average velocity (0.93, P < 0.001) and peak velocity measurements (r = 0.91, P = 0.002), although the correlation coefficient for flow rates was 0.88 (P = 0.004). Blurring of the vessel margins was consistently observed on magnitude images acquired with the partial Fourier method, causing overestimation of the vessel area and some error to the flow measurements. Conclusion: Partial Fourier PC MR is able to provide comparable average and peak velocity values when using 1 NEX PC MRI as a reference.
AB - Purpose: To validate partial Fourier phase contrast magnetic resonance (PC MR) with full number of excitation (NEX) PC MR measurements in vitro and in vivo. Materials and Methods: MR flow measurements were performed using a partial Fourier and a full NEX PC MR sequence in a flow phantom and in 10 popliteal and renal arteries of 10 different healthy volunteers. Average velocity, peak velocity, and flow results were calculated and compared with regression analysis. Results: Excellent correlations in average velocities (r = 0.99, P < 0.001), peak velocities (r = 0.99, P < 0.001), and flow rates (r = 0.98, P < 0.001) were demonstrated in vitro between the two different acquisitions. For the popliteal arteries there was excellent correlation between peak velocities for both acquisitions (r = 0.98, P < 0.0001); the correlation of average velocity measurements when using all data points in the cardiac cycle for all volunteers was 0.96 (P < 0.001). For the renal arteries the same comparison resulted in a good correlation for average velocity (0.93, P < 0.001) and peak velocity measurements (r = 0.91, P = 0.002), although the correlation coefficient for flow rates was 0.88 (P = 0.004). Blurring of the vessel margins was consistently observed on magnitude images acquired with the partial Fourier method, causing overestimation of the vessel area and some error to the flow measurements. Conclusion: Partial Fourier PC MR is able to provide comparable average and peak velocity values when using 1 NEX PC MRI as a reference.
KW - Blood vessels, MR
KW - Blood vessels, flow dynamics
KW - Magnetic resonance (MR), phase imaging
KW - Magnetic resonance (MR), vascular studies
KW - Phantoms
UR - http://www.scopus.com/inward/record.url?scp=30744462602&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=30744462602&partnerID=8YFLogxK
U2 - 10.1002/jmri.20472
DO - 10.1002/jmri.20472
M3 - Article
C2 - 16315213
AN - SCOPUS:30744462602
SN - 1053-1807
VL - 23
SP - 42
EP - 49
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 1
ER -