Comparison of antifactor Xa and activated partial thromboplastin time monitoring for heparin dosing in vascular surgery patients: A single-center retrospective study

Elsie Rizk, Allison D. Wilson, Michelle U. Murillo, David R. Putney

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: Vascular surgery patients often require anticoagulation with intravenous unfractionated heparin monitored through antifactor Xa (anti-Xa) levels or the activated partial thromboplastin time (aPTT). This study compares the 2 monitoring strategies in terms of major bleeding events in the vascular surgery population. Methods: This was a single-center, retrospective study that included patients treated with a pharmacy-managed heparin protocol monitored by either anti-Xa or aPTT after vascular surgery. The primary outcome was the percentage of patients experiencing major bleeding events after procedure. Secondary outcomes evaluated minor bleeding episodes, postprocedure packed red blood cell transfusions, and the incidence of thrombotic events. In a secondary analysis, simultaneously measured anti-Xa and aPTT values were identified and analyzed for discordance. Results: Major bleeding occurred in 12/72 patients (17%) on the anti-Xa-monitored protocol versus 5/62 patients (8%) on the aPTT-monitored protocol (P = 0.19). Minor bleeding episodes were documented in 10% of the patients in the anti-Xa group versus 6% in the aPTT group (P = 0.54). There were no significant differences between the 2 groups in packed red blood cell transfusions and thrombotic events. Of 109 pairs of simultaneously measured anti-Xa and aPTT values, 39 pairs (36%) showed relatively high aPTT values compared with corresponding anti-Xa levels. Nine patients who had these discordant test results experienced bleeding while their heparin drip was titrated based on lower anti-Xa values. Conclusions: The use of anti-Xa levels for heparin titration showed higher rates of major bleeding complications in vascular surgery patients compared with aPTT monitoring, but no significant difference was identified in this study. Vascular surgery patients with relatively high aPTT to anti-Xa values may have an increased risk of bleeding complications when heparin is titrated based on anti-Xa levels.

Original languageEnglish (US)
Pages (from-to)151-155
Number of pages5
JournalTherapeutic Drug Monitoring
Volume40
Issue number1
DOIs
StatePublished - Feb 2018

Keywords

  • Anti-Xa
  • Anticoagulation
  • Unfractionated heparin
  • Vascular surgery

ASJC Scopus subject areas

  • Pharmacology
  • Pharmacology (medical)

Fingerprint

Dive into the research topics of 'Comparison of antifactor Xa and activated partial thromboplastin time monitoring for heparin dosing in vascular surgery patients: A single-center retrospective study'. Together they form a unique fingerprint.

Cite this