TY - JOUR
T1 - Comparison of Longitudinal Skeletal Thigh Muscle Findings With Magnetic Resonance Imaging in Patients With Peripheral Artery Disease With–Versus–Without Diabetes Mellitus
AU - Gimnich, Olga A.
AU - Ortiz, Carlos B.
AU - Yang, Eric Y.
AU - Chen, Changyi
AU - Virani, Salim S.
AU - Kougias, Panos
AU - Lumsden, Alan B.
AU - Morrisett, Joel D.
AU - Ballantyne, Christie M.
AU - Nambi, Vijay
AU - Brunner, Gerd
N1 - Funding Information:
This work was supported by grants R01HL137763 and K25HL121149 from the National Institutes of Health, Bethesda, Maryland, to Dr. Brunner, and grant 13BGIA16720014 from the American Heart Association, Dallas, Texas, to Dr. Brunner.
Funding Information:
Dr. Virani declares grant support from the Department of Veterans Affairs, NIH, the Tahir and Jooma Family, and an honorarium from the American College of Cardiology (Associate Editor for Innovations, acc.org). The remaining authors have no conflicts of interest to declare.
Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2022/10/15
Y1 - 2022/10/15
N2 - The aim of this secondary analysis of ELIMIT (The Effect of Lipid Modification on Peripheral Artery Disease after Endovascular Intervention Trial) was to determine longitudinal changes over 24 months in skeletal thigh muscle volumes and individual muscle compartments in patients with peripheral artery disease (PAD) with and without diabetes. A total of 48 patients with available magnetic resonance imaging of the distal superficial femoral artery at baseline and 2 years were included in this analysis. Muscle volumes and superficial femoral artery wall, lumen, and total vessel volumes were quantified. Intrareader reproducibility of muscle tracings was assessed with the intraclass correlation coefficient using a 2-way model. Baseline characteristics were similar between patients with PAD with and without diabetes, except for smoking history (p = 0.049), cholesterol levels (p <0.050), and calf walking pain (p = 0.049). Interobserver reproducibility of the muscle volume tracings was excellent for all muscle groups (all intraclass correlation coefficients >0.86, confidence interval 0.69 to 0.94). Total muscle and total leg volumes increased significantly between baseline and 24 months among patients with PAD without diabetes (31 ± 6.4 cm
3 vs 32 ± 7.0 cm
3, p <0.001; 18 ± 4.4 cm
3 vs 19 ± 4.8 cm
3, p = 0.045), whereas there was no change in patients with PAD and diabetes. Total muscle volume was inversely associated with age and body mass index in patients with PAD both with and without diabetes (p <0.05). In conclusion, magnetic resonance imaging-quantified thigh muscle volumes are highly reproducible and may be of interest in assessing PAD patients with and without diabetes.
AB - The aim of this secondary analysis of ELIMIT (The Effect of Lipid Modification on Peripheral Artery Disease after Endovascular Intervention Trial) was to determine longitudinal changes over 24 months in skeletal thigh muscle volumes and individual muscle compartments in patients with peripheral artery disease (PAD) with and without diabetes. A total of 48 patients with available magnetic resonance imaging of the distal superficial femoral artery at baseline and 2 years were included in this analysis. Muscle volumes and superficial femoral artery wall, lumen, and total vessel volumes were quantified. Intrareader reproducibility of muscle tracings was assessed with the intraclass correlation coefficient using a 2-way model. Baseline characteristics were similar between patients with PAD with and without diabetes, except for smoking history (p = 0.049), cholesterol levels (p <0.050), and calf walking pain (p = 0.049). Interobserver reproducibility of the muscle volume tracings was excellent for all muscle groups (all intraclass correlation coefficients >0.86, confidence interval 0.69 to 0.94). Total muscle and total leg volumes increased significantly between baseline and 24 months among patients with PAD without diabetes (31 ± 6.4 cm
3 vs 32 ± 7.0 cm
3, p <0.001; 18 ± 4.4 cm
3 vs 19 ± 4.8 cm
3, p = 0.045), whereas there was no change in patients with PAD and diabetes. Total muscle volume was inversely associated with age and body mass index in patients with PAD both with and without diabetes (p <0.05). In conclusion, magnetic resonance imaging-quantified thigh muscle volumes are highly reproducible and may be of interest in assessing PAD patients with and without diabetes.
KW - Diabetes Mellitus
KW - Humans
KW - Magnetic Resonance Imaging
KW - Muscle, Skeletal/blood supply
KW - Peripheral Arterial Disease/diagnosis
KW - Reproducibility of Results
KW - Thigh/diagnostic imaging
UR - http://www.scopus.com/inward/record.url?scp=85136312828&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85136312828&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2022.06.060
DO - 10.1016/j.amjcard.2022.06.060
M3 - Article
C2 - 35999068
AN - SCOPUS:85136312828
SN - 0002-9149
VL - 181
SP - 130
EP - 138
JO - American Journal of Cardiology
JF - American Journal of Cardiology