T1 - Electronic patient identification for sample labeling reduces wrong blood in tube errors
AU - on behalf of the BEST Collaborative
AU - Kaufman, Richard M.
AU - Dinh, Anh
AU - Cohn, Claudia S.
AU - Fung, Mark K.
AU - Gorlin, Jed
AU - Melanson, Stacy
AU - Murphy, Michael F.
AU - Ziman, Alyssa
AU - Elahie, Allahna L.
AU - Chasse, Danielle
AU - Degree, Lynsi
AU - Dunbar, Nancy M.
AU - Dzik, Walter H.
AU - Flanagan, Peter
AU - Gabert, Kimberly
AU - Ipe, Tina S.
AU - Jackson, Bryon
AU - Lane, Debra
AU - Raspollini, Elisabetta
AU - Ray, Charles
AU - Sharon, Yudit
AU - Ellis, Martin
AU - Selleng, Kathleen
AU - Staves, Julie
AU - Yu, Philip
AU - Zeller, Michelle
AU - Yazer, Mark
N1 - Publisher Copyright:
© 2018 AABB
PY - 2019/3
Y1 - 2019/3
N2 - BACKGROUND: Wrong blood in tube (WBIT) errors are a preventable cause of ABO-mismatched RBC transfusions. Electronic patient identification systems (e.g., scanning a patient's wristband barcode before pretransfusion sample collection) are thought to reduce WBIT errors, but the effectiveness of these systems is unclear. STUDY DESIGN AND METHODS: Part 1: Using retrospective data, we compared pretransfusion sample WBIT rates at hospitals using manual patient identification (n = 16 sites; >1.6 million samples) with WBIT rates at hospitals using electronic patient identification for some or all sample collections (n = 4 sites; >0.5 million samples). Also, we compared WBIT rates after implementation of electronic patient identification with preimplementation WBIT rates. Causes and frequencies of WBIT errors were evaluated at each site. Part 2: Transfusion service laboratories (n = 18) prospectively typed mislabeled (rejected) samples (n = 2844) to determine WBIT rates among samples with minor labeling errors. RESULTS: Part 1: The overall unadjusted WBIT rate at sites using manual patient identification was 1:10,110 versus 1:35,806 for sites using electronic identification (p < 0.0001). Correcting for repeat samples and silent WBIT errors yielded overall adjusted WBIT rates of 1:3046 for sites using manual identification and 1:14,606 for sites using electronic identification (p < 0.0001), with wide variation among individual sites. Part 2: The unadjusted WBIT rate among mislabeled (rejected) samples was 1:71 (adjusted WBIT rate, 1:28). CONCLUSION: In this study, using electronic patient identification at the time of pretransfusion sample collection was associated with approximately fivefold fewer WBIT errors compared with using manual patient identification. WBIT rates were high among mislabeled (rejected) samples, confirming that rejecting samples with even minor labeling errors helps mitigate the risk of ABO-incompatible transfusions.
AB - BACKGROUND: Wrong blood in tube (WBIT) errors are a preventable cause of ABO-mismatched RBC transfusions. Electronic patient identification systems (e.g., scanning a patient's wristband barcode before pretransfusion sample collection) are thought to reduce WBIT errors, but the effectiveness of these systems is unclear. STUDY DESIGN AND METHODS: Part 1: Using retrospective data, we compared pretransfusion sample WBIT rates at hospitals using manual patient identification (n = 16 sites; >1.6 million samples) with WBIT rates at hospitals using electronic patient identification for some or all sample collections (n = 4 sites; >0.5 million samples). Also, we compared WBIT rates after implementation of electronic patient identification with preimplementation WBIT rates. Causes and frequencies of WBIT errors were evaluated at each site. Part 2: Transfusion service laboratories (n = 18) prospectively typed mislabeled (rejected) samples (n = 2844) to determine WBIT rates among samples with minor labeling errors. RESULTS: Part 1: The overall unadjusted WBIT rate at sites using manual patient identification was 1:10,110 versus 1:35,806 for sites using electronic identification (p < 0.0001). Correcting for repeat samples and silent WBIT errors yielded overall adjusted WBIT rates of 1:3046 for sites using manual identification and 1:14,606 for sites using electronic identification (p < 0.0001), with wide variation among individual sites. Part 2: The unadjusted WBIT rate among mislabeled (rejected) samples was 1:71 (adjusted WBIT rate, 1:28). CONCLUSION: In this study, using electronic patient identification at the time of pretransfusion sample collection was associated with approximately fivefold fewer WBIT errors compared with using manual patient identification. WBIT rates were high among mislabeled (rejected) samples, confirming that rejecting samples with even minor labeling errors helps mitigate the risk of ABO-incompatible transfusions.
UR - http://www.scopus.com/inward/record.url?scp=85058422651&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85058422651&partnerID=8YFLogxK
U2 - 10.1111/trf.15102
DO - 10.1111/trf.15102
M3 - Article
C2 - 30549289
AN - SCOPUS:85058422651
SN - 0041-1132
VL - 59
SP - 972
EP - 980
JO - Transfusion
JF - Transfusion
IS - 3
ER -