Image-derived input function for human brain using high resolution PET imaging with [11C](R)-rolipram and [11C]PBR28

Paolo Zanotti-Fregonara, Jeih San Liow, Masahiro Fujita, Elodie Dusch, Sami S. Zoghbi, Elise Luong, Ronald Boellaard, Victor W. Pike, Claude Comtat, Robert B. Innis

Research output: Contribution to journalArticlepeer-review

41 Scopus citations

Abstract

Background: The aim of this study was to test seven previously published image-input methods in state-of-the-art high resolution PET brain images. Images were obtained with a High Resolution Research Tomograph plus a resolution-recovery reconstruction algorithm using two different radioligands with different radiometabolite fractions. Three of the methods required arterial blood samples to scale the image-input, and four were blood-free methods. Methods: All seven methods were tested on twelve scans with [11C](R)-rolipram, which has a low radiometabolite fraction, and on nineteen scans with [11C]PBR28 (high radiometabolite fraction). Logan VT values for both blood and image inputs were calculated using the metabolite-corrected input functions. The agreement of image-derived Logan VT values with the reference blood-derived Logan VT values was quantified using a scoring system. Using the image input methods that gave the most accurate results with Logan analysis, we also performed kinetic modelling with a two-tissue compartment model. Results: For both radioligands the highest scores were obtained with two blood-based methods, while the blood-free methods generally performed poorly. All methods gave higher scores with [11C](R)-rolipram, which has a lower metabolite fraction. Compartment modeling gave less reliable results, especially for the estimation of individual rate constants. Conclusion: Our study shows that: 1) Image input methods that are validated for a specific tracer and a specific machine may not perform equally well in a different setting; 2) despite the use of high resolution PET images, blood samples are still necessary to obtain a reliable image input function; 3) the accuracy of image input may also vary between radioligands depending on the magnitude of the radiometabolite fraction: the higher the metabolite fraction of a given tracer (e.g., [11C]PBR28), the more difficult it is to obtain a reliable image-derived input function; and 4) in association with image inputs, graphical analyses should be preferred over compartmental modelling.

Original languageEnglish (US)
Article numbere17056
JournalPLoS ONE
Volume6
Issue number2
DOIs
StatePublished - 2011

ASJC Scopus subject areas

  • General

Fingerprint

Dive into the research topics of 'Image-derived input function for human brain using high resolution PET imaging with [11C](R)-rolipram and [11C]PBR28'. Together they form a unique fingerprint.

Cite this