Pectus excavatum with delayed diagnosis of implant tear on MRI apparently causing recurrent postoperative seromas: A case report

Arti R. Iyer, Daniel K. Powell, Robert D. Irish, Kevin R. Math

Research output: Contribution to journalArticlepeer-review

Abstract

Seroma formation is the most common early postoperative complication after pectus excavatum repair, but later seromas are rare. While many seromas eventually resorb or decrease in size after aspiration, our case demonstrates recurrent seroma formation as a late complication of pectus excavatum repair in a patient with an implant tear. Postoperative seromas can result in prolonged chest wall pain, large chest wall masses, and increased mass effect on the heart with potential risk for resultant right ventricular outflow obstruction. This case report illustrates a solid silicone implant tear. Though rare, early recognition may help to decrease the likelihood of recurrent postoperative seromas.

Original languageEnglish (US)
Pages (from-to)1153-1156
Number of pages4
JournalSkeletal Radiology
Volume44
Issue number8
DOIs
StatePublished - Dec 2 2015

Keywords

  • Pectus excavatum
  • Recurrence
  • Seroma
  • Silicone implant

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Pectus excavatum with delayed diagnosis of implant tear on MRI apparently causing recurrent postoperative seromas: A case report'. Together they form a unique fingerprint.

Cite this