TY - JOUR
T1 - Technical and anatomical factors affecting intra-arterial chemotherapy fluoroscopy time and radiation dose for intraocular retinoblastoma
AU - Area, Corey
AU - Yen, Christopher J.
AU - Chévez-Barrios, Patricia
AU - Herzog, Cynthia
AU - Kan, Peter
AU - Zheng, Wei
AU - Lin, Frank
AU - Chintagumpala, Murali
AU - Gombos, Dan
AU - Chen, Stephen R.
N1 - Funding Information:
Competing interests ch reports personal fees from Merck, outside the submitted work. Dg reports non-financial support and other from children’s Oncology group, during the conduct of the study; grants from houseman/Wilkins Ophthalmological Foundation, personal fees, and non-financial support from abbvie, other from 3T Ophthalmics, other from aura Biosciences, outside the submitted work.
Publisher Copyright:
© Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2019/12/1
Y1 - 2019/12/1
N2 - Background Intra-arterial chemotherapy has an increasingly prominent role in the management of retinoblastoma. One concern regarding this technique is procedural radiation exposure. Objectives To examine the effects of our institution's procedural technique on fluoroscopy parameters for patients undergoing intra-arterial chemotherapy infusions for intraocular retinoblastoma. Secondary goals included describing the effect of anatomical variations of the carotid siphon and ophthalmic artery on radiation dose. Methods A retrospective review of pediatric patients with retinoblastoma referred to interventional neuroradiology for chemosurgery was performed. Techniques were classified as: A (1.2 Fr or 1.5 Fr microcatheter with continuous verapamil flush, advanced without guide through a 2 Fr sheath) or B (1.5 Fr or 1.7 Fr microcatheter advanced within a 4 Fr base catheter, through a 4 Fr sheath). Statistical analysis was performed to determine if there was a significant difference in fluoroscopy parameters based on technique or due to anatomical variation. Results 26 patients were treated with 94 intra-arterial chemotherapy infusions. 34 procedures were performed using technique A and 60 using technique B. Mean fluoroscopy time (4.75 min), fluoroscopy dose (23.3 mGy), and dose-area product (DAP; 85.2 μGy.m 2) for technique A were significantly lower (p value <0.05) than for technique B, 14.0 min., 191 mGy, and 586 μGy.cm 2, respectively. Conclusions Microcatheter-only technique with continuous verapamil infusion resulted in decreased fluoroscopy times, DAP, and radiation doses at our institution for the treatment of intraocular retinoblastoma. Furthermore, our fluoroscopy times using this technique are the lowest reported in the current literature. Additionally, our anatomical analysis has demonstrated a positive correlation between increasing vessel tortuosity and fluoroscopy times.
AB - Background Intra-arterial chemotherapy has an increasingly prominent role in the management of retinoblastoma. One concern regarding this technique is procedural radiation exposure. Objectives To examine the effects of our institution's procedural technique on fluoroscopy parameters for patients undergoing intra-arterial chemotherapy infusions for intraocular retinoblastoma. Secondary goals included describing the effect of anatomical variations of the carotid siphon and ophthalmic artery on radiation dose. Methods A retrospective review of pediatric patients with retinoblastoma referred to interventional neuroradiology for chemosurgery was performed. Techniques were classified as: A (1.2 Fr or 1.5 Fr microcatheter with continuous verapamil flush, advanced without guide through a 2 Fr sheath) or B (1.5 Fr or 1.7 Fr microcatheter advanced within a 4 Fr base catheter, through a 4 Fr sheath). Statistical analysis was performed to determine if there was a significant difference in fluoroscopy parameters based on technique or due to anatomical variation. Results 26 patients were treated with 94 intra-arterial chemotherapy infusions. 34 procedures were performed using technique A and 60 using technique B. Mean fluoroscopy time (4.75 min), fluoroscopy dose (23.3 mGy), and dose-area product (DAP; 85.2 μGy.m 2) for technique A were significantly lower (p value <0.05) than for technique B, 14.0 min., 191 mGy, and 586 μGy.cm 2, respectively. Conclusions Microcatheter-only technique with continuous verapamil infusion resulted in decreased fluoroscopy times, DAP, and radiation doses at our institution for the treatment of intraocular retinoblastoma. Furthermore, our fluoroscopy times using this technique are the lowest reported in the current literature. Additionally, our anatomical analysis has demonstrated a positive correlation between increasing vessel tortuosity and fluoroscopy times.
KW - embolic
KW - malignant
KW - orbit
KW - pediatrics
KW - technique
UR - http://www.scopus.com/inward/record.url?scp=85067345487&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85067345487&partnerID=8YFLogxK
U2 - 10.1136/neurintsurg-2019-014910
DO - 10.1136/neurintsurg-2019-014910
M3 - Article
C2 - 31197028
AN - SCOPUS:85067345487
SN - 1759-8478
VL - 11
SP - 1273
EP - 1276
JO - Journal of neurointerventional surgery
JF - Journal of neurointerventional surgery
IS - 12
ER -