Abstract

The human aortic valve is normally a tricuspid structure but may occur as bicuspid or quadricuspid structures (Figure 1). Biscuspid aortic valve (BAV) is one of the most common congenital heart anomalies and the most common congenital anomaly in adults, occurring in 0.5-2% of the population based on echocardiography and autopsy series. It is an inherited defect that appears to occur in an autosomal dominant pattern. BAV is the cause of aortic stenosis in 70-85% of pediatric cases and about 50% of adult cases. Indications for aortic valve replacement (AVR) in BAVs is the same as rheumatic or senile calcific degeneration aortic valves. BAVs are different, however, in that the tissue pathology is not limited to the valves' leaflets but extends from the left ventricular outflow tract to the ascending thoracic aorta. BAVs are associated with several congenital anomalies, infective endocarditis, and acute thoracic aortic emergencies such as aneurysm and dissection. These associations lead to surgical considerations different from other aortic valve pathologies.

Original languageEnglish (US)
Pages (from-to)29-32
Number of pages4
JournalMethodist DeBakey cardiovascular journal
Volume6
Issue number1
DOIs
StatePublished - 2010

ASJC Scopus subject areas

  • Medicine(all)

Fingerprint

Dive into the research topics of 'Bicuspid aortic valve and associated aortopathy: surgical considerations.'. Together they form a unique fingerprint.